BLYWT - FIREPREP 1000 FUEL CONDITIONER

  • MSDS: BLYWT
  • Manufacturer: NALCO CHEMICAL CO
  • Product Name: FIREPREP 1000 FUEL CONDITIONER
  • National Stock Number: 9150-00N023993
Product Identification

Product ID:FIREPREP 1000 FUEL CONDITIONER
MSDS Date:01/20/1988
FSC:9150
NIIN:00N023993
MSDS Number: BLYWT

Responsible Party
NALCO CHEMICAL CO
ONE NALCO CENTER
NAPERVILLE, IL 60563-1198
US

Emergency Phone: 708-920-1510

Info Phone: 708-305-1000

Preparer: JOHN J KASPER

Cage: 89524

Contractor
ONDEO NALCO COMPANY
NAPERVILLE, IL 60563-1198 US

Telephone: (630) 305-1000

Cage: 89524

Ingredients

IMIDAZOLINE; (HYDROXYETHYLALKYL)

CAS: 61791-39-7

Fraction By Weight: 1.19%


ALIPHATIC PETROLEUM DISTILLATES

CAS: 68476-30-2

Fraction By Weight: 40%+

OSHA PEL 100 PPM

ACGIH TLV: 100 PPM


SOLVENT NAPHTHA; (HEAVY AROMATIC NAPHTHA)

CAS: 64742-94-5

RTECS: WF3100000

Fraction By Weight: 1-10%


INDIV RXN OF PATIENT, THE PHYSICIAN'S

RTECS: 9999999ZZ


IF UNCON, HAVING TROUBLE BRTHG/IN

RTECS: 9999999ZZ


MUCOSAL DMG MAY CONTRAINDICATE THE USE OF GASTRIC

RTECS: 9999999ZZ


AND CONVULSIONS MAY BE NEEDED.

RTECS: 9999999ZZ


FOR LRG INDOOR, EVAC EMPLOYEES & VENT AREA.

RTECS: 9999999ZZ


EQUIP.KEEP SPILL AWAY FROM HEAT, SPARKS, FLAMES &

RTECS: 9999999ZZ


THE AIRBORNE CONC EXCEEDS THE TLV.THIS PROD IS TOX TO

RTECS: 9999999ZZ


PONDS, STREAMS, WATERWAYS OR PUBLIC WATER SUPPLIES.

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:EYE: CORR W/POSS PERM DMG DEPENDING ON
LENGTH OF EXPOS & ON FIRST AID ACTION GIVEN. SKIN: CORR, POSS
RESULTING IN THIRD DEGREE BURNS DEPENDING ON LENGTH OF EXPOS & ON
FIRST AID ACTION GIVEN. CAN BE HA RMFUL IF ABSORBED. INGEST: CAN BE
HARMFUL/FATAL. INHAL: PRLNGD INHAL OF MIST/VAP MAY CAUSE NAUS,
DIZZ, (SUPP DATA)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:A REVIEW OF AVAILABLE DATA DOES NOT IDENTIFY
ANY SYMPTOMS FROM EXPOSURE.
Medical Cond Aggravated by Exposure:A REVIEW OF AVAILABLE DATA DOES NOT
IDENTIFY ANY WORSENING OF EXISTING CONDITIONS.

First Aid

First Aid:EYE:IMMED FLUSH FOR AT LEAST 15 MIN WHILE HOLDING LIDS
OPEN.CALL MD IMMED.SKIN:IMMED FLUSH W/WATER FOR AT LEAST 15 MIN.FOR
LRG SPLASH,FLOOD BODY UNDER SHOWER.CALL MD IMMED.INGEST:DO NOT
INDUCE VOMIT.G IVE WATER.CALL MD IMMED.INHAL:REMOVE TOFRESH
AIR.TREAT SYMP.CALL MD IMMED.IF BRTHG STOPS,GIVE CPR.ADMINISTER
OXYGEN.CALL MD IMMED.NOTE TO MD:NO SPECIFIC ANTIDOTE IS KNOWN.BASED
ON THE (ING 4)

Fire Fighting

Flash Point Method:PMCC
Flash Point:170F,77C
Extinguishing Media:BASED ON NFPA GUIDE, DRY CHEM, ALCOHOL FOAM,
CO*2/OTHER EXTING AGENT SUITABLE FOR CLASS B FIRES. USE WATER (SUPP
DATA)
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA & FULL
PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:MAY EVOLVE NO*X UNDER FIRE CONDITIONS.

Accidental Release

Spill Release Procedures:SM LIQ:CONTAIN W/ABSORB MATL,SUCH AS CLAY,
SOIL/ANY COMMERCIALLY AVAIL ABSORB.SHOVEL RECLAIMED LIQ & ABSORB IN
RECOVERY/SALVAGE DRUMS FOR DISP.LRG LIQ:DIKE TO PVNT FURTHER
MOVEMENT & RECLAIM IN RECOVE RY/SALVAGE DRUMS/TANK TRUCK FOR DISP.
(ING 8)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:KEEP AWAY FROM HEAT, AND OPEN FLAME.
KEEP CNTNR CLSD WHEN NOT IN USE. AVOID BRTHG VAP. USE W/ADEQ VENT.
DO NOT TAKE INTERNALLY.
Other Precautions:EMPTY CNTNRS MAY CONTAIN RESIDUAL PRODUCT. DO NOT
REUSE CNTNR UNLESS PROPERLY RECONDITIONED. CAUSES SEVERE EYE AND
SKIN DMG. DO NOT GET IN EYES, ON SKIN, OR ON CLOTHING.

Exposure Controls

Respiratory Protection:IF POSS TO GENERATE SIGNIFICANT LEVELS OF
VAPS/MISTS, A NIOSH/MSHA APPRVD OR EQUIVALENT RESP IS REC. FOR LRG
SPILLS, ENTRY IN LRG TANKS, VESSELS/ENCLSD SM SPACES W/INADEQ VENT,
A NIOSH/MSHA APPRVD SCB A IS REC.
Ventilation:GENERAL VENT IS REC. ADDITIONALLY, LOCAL EXHAUST VENT IS
RECOMMENDED WHERE VAPS, MISTS OR AEROSOLS MAY BE RELEASED.
Protective Gloves:PROTECTIVE GLOVES.
Eye Protection:CHEM WORK GOG & FULL LENGTH FSHLD.
Other Protective Equipment:BOOTS, APRON. A FULL SLICKER SUIT IS
RECOMMENDED IF GROSS EXPOSURE IS POSS. EYE WASH FOUNTAIN & SAFETY
SHOWER IS REC.
Work Hygienic Practices:IF CLOTHING IS CONTAMINATED, REMOVE CLOTHING &
THORO WASH AFFECTED AREA. LAUNDER CONTAM CLOTHING BEFORE REUSE.
Supplemental Safety and Health
EXT MEDIA:TO COOL CNTNRS EXPSD TO FIRE.FOR LRG FIRES,USE WATER
SPRAY/FOG,THORO DRENCHING BURNING MATL.MATL TO
AVOID:PERMANGANATES)WHICH CAN GENERATE HEAT, FIRES, EXPLO & RELEASE
OF TOX FUMES.HLTH HAZ: LIGHT-HEADEDNESS, VOMIT/UNCON DEPENDINGON
LENGTH OF EXPOS & FIRST AID ACTION GIVEN.CAN BE CORR TO MUC MEMB &
LUNGS.

Chemical Properties

HCC:V4
Spec Gravity:0.90 @ 60F
Solubility in Water:INSOLUBLE
Appearance and Odor:DARK AMBER LIQUID WITH A HYDROCARBON ODOR.

Stability

Stability Indicator/Materials to Avoid:YES
AVOID CONT W/STRONG OXIDIZERS (E.G. CHLORINE, PEROXIDES, CHROMATES,
NITRIC ACID, PERCHLORATES, CONC OXYGEN, (SUPP DATA)
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:IN EVENT OF COMBUST CO, CO*2, NO*X MAY
BE FORMED.

Disposal

Waste Disposal Methods:AS A NON-HAZARDOUS LIQUID WASTE, IT SHOULD BE
SOLIDIFIED BEFORE DISPOSAL TO A SANITARY LANDFILL. CAN BE
INCINERATED IN ACCORDANCE WITH LOCAL, STATE AND FEDERAL
REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.